Home / Blog / Will a heat pump work with my radiators?
Question answered

Will a heat pump work with my radiators?

20 November 2026 · 4 minute read · Facts checked 24 October 2026

In most homes, yes. An air source heat pump heats the same radiators a boiler does, but it sends cooler water round them, so each radiator gives out less heat than it did before. Some rooms keep their radiators exactly as they are, while others need a larger one to stay warm on a cold day. A room by room heat loss calculation at your survey is what tells you which rooms, if any, need a change, before any work starts.

Will a heat pump work with my radiators?
The short answer

What the numbers say

A heat pump works best when the water in your heating runs cooler than a boiler would send it. That is the whole reason radiators come up at all.

45°CA typical flow temperature for a heat pumpThe water leaving the heat pump on its way to the radiators
75°CA typical flow temperature for a gas boilerThe temperature most radiators are rated at
93%of homes in a government funded trial needed at least one radiator changedEnergy Systems Catapult, Electrification of Heat project
Why it happens

Why a heat pump runs your radiators cooler

A heat pump uses less electricity for every unit of heat when it makes water at a lower temperature. Push it to make very hot water and it still works, but it costs more to run. So a well designed system keeps the water as cool as the house allows, and lets the radiators run warm for longer instead of hot in short bursts.

A gas boiler

  • Sends water round at about 70°C to 75°C
  • Radiators feel hot to touch
  • Heats the room quickly, then switches off

A heat pump

  • Sends water round at about 35°C to 55°C
  • Radiators feel warm rather than hot
  • Runs steadily for longer to keep rooms at temperature
The radiator itself

How much heat a radiator gives at heat pump temperatures

Radiators are sold with a heat output measured at boiler temperatures. When the water is cooler, the same radiator gives out less. At typical heat pump temperatures, where the water is about 30 degrees warmer than the room, a radiator gives out roughly half of its boiler rating.

Heat from the same radiator at heat pump temperaturesRoughly half
0%100% of its boiler rating

Based on the standard correction factor of about 0.51 used to size radiators when the water is 30 degrees warmer than the room. Warmer water closes the gap, but costs more to run.

The fixes

What can be done in a room that needs more heat

Most common

A bigger radiator in the same place

A taller or wider radiator, often fitted where the old one was, so the room layout stays the same.

Same wall space

A double or triple panel radiator

Extra panels add heat output without taking up much more of the wall.

Less heat needed

Better insulation

Loft insulation, draught proofing or better windows cut how much heat a room loses, so the existing radiator may be enough.

New floors

Underfloor heating

It suits heat pumps well because it runs at low temperatures. It is usually limited to the ground floor and is a bigger job.

What you might hear

Two things people often get wrong

You might hearYou have to replace every radiator in the house.
The factsNot usually. In the Electrification of Heat trial, 93% of homes needed at least one radiator changed, which is very different from all of them. Rooms that already have enough radiator for their size often stay as they are.
You might hearHeat pumps cannot heat a home with radiators properly.
The factsThey can. The radiators just need to be big enough for each room at the lower water temperature. That is exactly what the heat loss calculation checks.
How it is worked out

How AuraNord decides which radiators stay

Nothing is guessed. At your home survey, an AuraNord engineer works through the house room by room:

  1. Measure each room and note the walls, windows, floor and loft insulation.
  2. Work out how much heat each room loses on a cold winter day.
  3. Check the heat each existing radiator gives out at the planned water temperature.
  4. Mark any room where the radiator falls short, and choose the replacement.
  5. Show every radiator change on your quote, so you know before any work starts.
After it is fitted

Controls and guarantees

Controls
Ideal's Halo Air controls come as standard, with heating and hot water scheduling and an app on the Wi-Fi versions
Insurance backed guarantee
2 years through Quality Mark
Workmanship guarantee
12 months, separate from the Quality Mark guarantee
Survey
Room by room heat loss calculation, plus checks on pipework, radiators and the hot water cylinder

If you are planning other work, such as new windows or loft insulation, mention it at the survey. It can change how much heat each room needs, and so which radiators need to change.

Book your free home survey with AuraNord and find out exactly which radiators, if any, need to change in your home.

Get a survey

Questions people ask

Can a heat pump work with old radiators?

Yes, as long as each radiator is big enough for its room at the lower water temperature a heat pump uses. Age matters less than size. The heat loss calculation at your survey shows which ones are big enough.

Why are heat pump radiators bigger?

Because the water inside them is cooler. A radiator gives out roughly half its boiler rated heat when the water is about 30 degrees warmer than the room, so a room that needs the same heat may need a larger radiator.

Will my radiators feel cold with a heat pump?

They will feel warm rather than hot. The heat pump runs for longer at a lower temperature, which keeps the room comfortable without the radiator being hot to touch.

Do I need underfloor heating for a heat pump?

No. Radiators work well when they are sized correctly. Underfloor heating suits heat pumps too, but it is a bigger job and is usually limited to the ground floor.

How do I know which radiators need changing?

A room by room heat loss calculation, done at a home survey, compares the heat each room needs with the heat each radiator gives out. Any change shows on your quote before work starts.

Where these facts come from
  1. Energy Systems Catapult, Electrification of Heat home surveys and install report: 93% of homes that had a heat pump installed needed at leas…checked 2026-10-24
  2. Elegant Radiators heat pump sizing guide: correction factor (about 0.51 at a 30 degree difference), heat pump flow around 45°C, boiler basel…checked 2026-10-24
  3. Nesta: not every home needs bigger radiators; double or triple panels add output; underfloor heating suits heat pumps and is usually ground …checked 2026-10-24
  4. Ideal Heating Halo Air specification: single and 2 zone versions, heating and hot water control, Wi-Fi app versions, load compensating contr…checked 2026-10-24
  5. AuraNord homepage: survey includes heat loss calculation, pipework, radiators and cylinder sizing; free home surveychecked 2026-10-24